1
Recent Progress and Future Perspective on Condition Monitoring
and Diagnostic Techniques for Power Equipments in China
2 Insulation Condition Assessment of Power Equipments
in Electrical Assets Based on On-Line Monitoring of Partial
Discharges
3 Recent Progress and Future Perspective on Condition
Monitoring and Diagnostic Techniques for Power Equipment
in Japan
4 Recent Progress and Future Perspectives on Condition
Monitoring and Diagnostics for Power Equipment in Korea
5 The comparison study of PD measurement with conventional
method and unconventional method
6 Advances in PD Measuring System Techniques: Parallel
Synchronous Detection, Time Domain and Frequency Domain
Processing for Improved Sensitivity
7 Distinction of the Partial Discharge Source in Oil by
Two Frequency Correlation Method
8 Dependence of Partial Discharge Characteristics at Spacer
Surface on Particle Size in SF6 Gas Insulated System
9 Application of Partial Discharge Monitoring to Impulse
Damaged Polymeric Insulation
10 PD Patterns in Oil-Impregnated Insulation:A Comparative
Study
11 Diagnosis of Insulation Conditions : Interpretation
of Partial Discharges from f-q-n pattern, Pulse-Sequence
and Pulse Waveform
12 Ultra-high Frequency Spectral Characteristics of Partial
Discharge in Insulation Oil
13 Partial Discharge Characteristics in UHF-band of Composite
Insulation System Including Various Artificial Defects
in Transformer
14 Partial Discharge Modelling Based on a Cylindrical
Model in Solid Dielectrics
15 Fundamental Differences of the PD Measure-ment according
to IEC 60270 and in UHF range
16 Feature Extraction Methods for Time Frequency Energy
Distribution of PD Pulse
17 On-line Insulation Diagnostic System and Off-line PD
Monitoring with HVAC Testing
18 Comparing IEC60270 and RF Partial Discharge Patterns
19 Inverted Diagram of Calibration for Partial Discharge
Measuring
20 Investigation of PD Electromagnetic Wave Characteristics
in GIS
21 Classification of Defects and Evaluation of Electrical
Tree Degradation in Cable Insulation Using Pattern Recognition
Method and Weibull Process of Partial Discharge
22 Partial Discharge Characteristics of the Ultra-High
Voltage Cable Insulators according to the Measuring Temperature
23 Change in Pattern of Void-Type PD with Ageing
24 Partial Discharge Pattern Analysis in Cylindrical Insulators
Model of Transformer
25 Identification of Multiple Partial Discharge Sources
26 Status and Application Foreground of Ultraviolet Technology
on Fault Detection of Power Devices
27 The Use of Conductivity Factors for Estimating the
Degradation State of Insulation Systems of Medium-Power
Electrical Machines
28 Intricate Aspects Of Turbogenerator Endwinding Vibration
Monitoring Based On Data Analysis
29 On-line Calculation Model of Thermal Stress of Steam
Turbine Rotor Based On Integrated Modular Modeling Software
30 Development of Diagnosis Algorithm for Induction Motor
Using Flux Sensor
31 An Inverter-Embedded Stator Winding Insulation Quality
Assessment Technique for AC Machines
32 A Practical Bearing Fault Diagnoser
33 Off-Line PD Diagnosis for Stator Winding of Rotating
Machines using UWB Sensors
34 Practical Implementation of a Remote and Sensorless
Stator Resistance-Based Thermal Protection Method
35 A Case Study of Condition-Based Maintenance of a 202-MVA
Hydro-Generator
36 Web-based PD monitoring of a Generator in Loforsen
Sweden
37 A Subspace-Based Rejection Method for Detecting Bearing
Fault in Asynchronous Motor
38 Research of Remote Condition Monitoring System for
Turbo-generator Unit Based on B/S Model
39 Steam Turbine Rotor Thermal Stress on-line Monitoring
Based on XDPS
40 Stress and Fatigue Life Monitoring of High Temperature
Bearing Elements Based on the Solution of Inverse Conduction
Problem
41 Non-invasive On-line Detection of Winding Faults in
Induction Motors -A Review
42 Online Performance Test Software and Its Application
for Large Capacity Combined-cycle Units
43 A Survey of Testing and Monitoring Methods for Stator
Insulation Systems in Induction Machines
44 Comparison of On-line and Off-line PD Measuring System
for Hydro Generator Stator Winding
45 Fault Diagnosis Way Based on subsection Spectrum zoom
analysis by CZT for Squirrel Cage Induction Motors
46 Experience With Continuous On-Line Partial Discharge
Monitoring of Generators And Motors
47 The Application of Modal Analysis in Fault Diagnosis
of AC Motor
48 The Application of Zoom FFT Technique to the Extraction
of Fault Character of Induction Motor
49 Design of Monitoring and Fault Diagnosis System on-line
for certain Gas Turbo-generator set
50 Methods for Thermal Protection of Medium Voltage Induction
Motors - A Review
51 Investigation of Water Treeing - Electrical Treeing
Transition in Power Cables
52 Charge Transport and Electroluminescence in Insulating
Polymers
53 Experimental Research on the Streaming Electrification
of Transformer Oil under Aging
54 Experimental Model of Aging Mechanisms of On-load Tap
Changer Contacts
55 Analysis of Deterioration by Partial Discharge of XLPE
using GCMS and FTIR
56 Retrofit with Hybrid Insulation System of a Failed
Power Transformer
57 Research on Electrical Aging Lifetime Model of Insulation
Material under High Voltage Square Impulses for Inverter-Fed
Motors
58 Phase-Resolved Measurement and Modelling of Electroluminescence
Phenomenon in Polyethylene Subjected to High Electrical
Stress
59 A Practical Investigation on the Correlation between
Aging and the Dissipation Factor Value of Mica Insulated
Generator Windings
60 Analysis of Gasses Generated by Electrical Discharges
in Low Viscosity Silicone Oil
61 Study on the Interfacial Properties at the OTS Treated
SiO2 Film
62 Thermal Failure of Transformers
63 New Diagnostic Method of Winding Insulation Degradation
in Power Transformers based on Partial Discharge Characteristics
64 Effects of Temperature on Dielectric properties of
Rhicinnus Oils as Insulating Liquid
65 Thermal Instability on TR-XLPE 12/20 kV Ground Cable:
Non Adiabatic and Adiabatic Comparison Method
66 Effect of Antioxidants on Thermal Degradation of EPDM
and XLPE
67 DMA Properties of Semiconductive Composites in Power
Cables by Dual Filler System
68 The Effect of Thermal Ageing on the Electrical Characteristics
of Insulating Oil for Pole Transformers
69 Failure of a Big Transformer in HPP - Assessment of
Damage, Repair and Tests
70 On-site Application and Improvement of Water Tree Deterioration
Diagnosis for XLPE Cable by Residual Charge Method
71 Analysis on Insulation Aging Failure of Pulse Capacitor
72 Gaining Control on Anomalous Discharge as an Effective
Way to Increase Reliability of Work of Outdoor HV Insulators
73 Electric Field Determination in DC Polymeric Power
Cable in the Presence of Space Charge and Temperature
Gradient under dc Conditions
74 Analysis of AC Breakdown of Composite-Insulation depending
on Gas Pressure and Solid Insulation Thickness
75 Role of the Voltage Zero-crossing in the Growth of
Water Trees
76 Interfacial Characteristics of Space Charge in Multi-layer
LDPE
77 The Study on Diagnostics for Aging Trend of Cable Termination
78 Non-Uniform Field Breakdown Characteristics of SF6/CF4
Mixtures at Various Pressures
79 Evaluation Method of Deterioration of Polyetheretherketone
using Dielectric Relaxation Characteristics
80 Sensitivity of UHF Coupler and Loop Electrode With
UHF Method and Their Comparison for Detecting Partial
Discharge in GIS
81 A Fault Detection and Service Restoration Method by
Shifting the Feeder Tie Switch for Ungrounded Distribution
System
82 Monitoring the SF6 Pressure Level in Metal-Enclosed
Switchgear to Detect Gas Leakages
83 A Study of Flashover Voltage of Artificially Polluted
Porcelain Disc Insulator under Natural Fog Conditions
84 Investigation on DC Flashover Performance of Porcelain
Insulators in High Altitude Areas
85 Behavior of Metallic Particles in a Single Phase Gas
Insulated System with Dielectric Coated Electrodes
86 EHV Circuit Breaker Condition Monitoring using Antenna-based
Coupling Methods
87 Non-Intrusive Partial Discharge Measurements of MV
Switchgears
88 Image Analysis on the Surface Hydrophobicity of Polluted
Silicone Rubber Insulators
89 Monitoring The Insulator Condition by On-line Voltage
Distribution Measurement
90 Research on Detection and Recognition of Partial Discharge
in Gas Insulated System
91 Practical Application of Diagnostic Method of Circuit
Breaker by Measuring Three Current Waveforms
92 Real Time Embedded Maintenance System of Hydro Generator
Excitation System
93 Design of On-line Monitoring Device for MOA used in
10kV Distribution Network
94 GIS Partial Discharge Examination and Classification
from the On-Line Measurements
95 Research of Monitoring Switching-generated Arcing Current
during Opening and Closing Process using Rogowski Coil
96 Development of the On-line iPDM System for the PD Diagnosis
for 25.8kV C-GIS
97 Motion of Free Conducting Particles in a Single Phase
Compressed Gas Insulated Bus duct with Electromagnetic
Field Effect
98 Research on the Model of HV SF6 Circuit Breaker Fault
Diagnosis Based on Fuzzy Theory
99 Partial Discharge Monitoring System for Cubicle Type
GIS
100 Influence of Metal Flange Cover of Insulation Spacers
on Propagation Properties of PD-induced Electromagnetic
Wave in GIS
101 Particle Size Identification in GIS by Ultra High
Speed Measurement of Partial Discharge
102 On-line Monitoring Technology for MOA on HV Transmission
Line
103 The characteristic of Silicon Rubber Insulators Contaminated
with Concrete
104 Application of Combined PD Sensor for GIS PD Detection
and Condition Monitoring
105 Lifetime Monitoring and Estimation Strategy for Large
Power Transformer
106 A Fast and Reliable Dielectric Diagnostic Method to
Determine Moisture in Power Transformers
107 Advanced On-site Diagnosis of Power Transformers
108 Verification of a Model-Based Diagnosis System for
On-Line Detection of the Moisture Content of Power Transformer
Insulations Using Finite Element Calculations
109 Use of Furan-in-Oil Analysis to Determine the Condition
of Oil Filled Power Transformers
110 Thermal Monitoring on Power Transformers
111 Automatic Thermal Monitoring on Power Transformers
112 New Tools for Diagnostic Measurements on Power Transformers
113 Failure Statistics and Power Transformer Condition
Evaluation by Dissolved Gas Analysis Technique
114 Failure Analysis & Diagnostics of Power Transformer
Using Dielectric dissipation factor
115 Condition Based Maintenance of Power Transformer:
A Case Study
116 Realization of Transformer Winding network from Sweep
frequency Response Data
117 Partial Discharges Multi-Targets Localization in Power
Transformers Based On Spatial-Spectrum Estimation
118 The simulation analysis of harmonics and Negative
sequence with Scott wiring transformer
119 Partial Discharge Detection Using Acoustic Emission
Method for a Waveguide Functional High-Voltage Cast-Resin
Dry-Type Transformer
120 Partial Discharge Signal Analysis Using HHT for Cast-Resin
Dry-Type Transformer
121 Analysis of Acoustic Signals Generated by Partial
Discharges in Insulation Oil
122 Multi-PD Sources Location by UWB RF Detection on Power
Transformers and a Case Study on-site
123 Remarkable Benefit Realization by Application of Strategic
Management in Power Transformer Condition Monitoring and
Diagnostic Systems
124 Linking Engineering Knowledge and Practical Experience
to Investment Planning by Means of Condition Based Risk
Management
125 An Assessment of Insulation Condition for Generator
Rotor Windings
126 Application of Statistical Tools for Assessing Service
Availability of High Voltage Power Cables
127 Experience with PD Measurements in GIS Maintenance
Concept
128 The experience of DP and Furan in Remnant Life Assessment
of Power Transformer
129 Thermal Condition Assessment for Power Transformers
Operated in Tropical Condition
130 The Reliability Evaluation Method of High Voltage
Overhead Transmission Lines
131 Structural Learning Approach to Replacing Unreliable
Units in a Power System
132 Condition Monitoring and Plenary Diagnostics Strategy
Based on Event Driven Threads
133 Study of Maintenance Strategy Support Tools for Electric
Power Apparatus
134 Development of CMMS (Computerized Maintenance Management
System) in Yogyakarta Electric Power Distribution Network
Company To Support The Strategic Maintenance
135 Optimization of Asset Management and Power System
Operation Based on Equipment Performance
136 Investigation on Test Schemes for Grounding Grids
Corrosion Diagnosis
137 Remaining Lifetime Modelling for Replacement of Power
Transformer Populations
138 Determination of the Optimal Moments for Investigating
Technical State of Primary Equipments for the Purpose
of Assuring the Safety Levels
139 The Asset Health Review for Managing Reliability Risks
Associated with Ongoing Use of Ageing System Power Transformers
140 Defining the Life of Major Assets
141 Development of a Power Facility Management System
using Reliability-centered Maintenance
142 Economic Evaluation of Different Rules of Insulation
Diagnosis
143 Analysis of integrated monitoring of HV electrical
equipment in power system
144 Condition Monitoring Plans of CLP Power Hong Kong
and its Roadmap to Condition Based Maintenance
145 Apparent Mobility and its Relationship with Ageing
in Polymeric Insulation Materials
146 Study of DC Corona Inception and Extinction Voltage
Measurement on Electrode Surfaces Using UV Corona Monitor
147 Multivariate Analysis for Investigation of Outdoor
Insulator Conditions
148 Moisture Ingress in Free Breathing Transformers
149 Frequency Response Analysis - Status of the Worldwide
Standardization Activities
150 Effect of Humidity on Breakdown of Low Density Polyethylene
Film due to Partial discharge
151 Correlation between UV-Vis Spectral Response and Furan
Measurement of Transformer Oil
152 Dissolved Gas Analysis of Faults in Bio-degradable
Oil Transformer Insulating Systems
153 The Effect of Atmospheric Factor on Various Test Gaps
Under Negative Impulse Voltages
154 Elongation of Overhead Line Conductors under combined
mechanical and thermal Stress
155 An Online Dynamic Capacity-Increase System of Transmission
Lines
156 Condition Monitoring on HV equipment in CLP Power
157 HV AC Generation Based on Resonant Circuits with Variable
Frequency for Testing of Electrical Power Equipment on
Site
1581 On-Line Condition Monitoring and Diagnostics of Power
Distribution Equipment
159 OHL Condition Monitoring and Engineering Solutions
to Cinch Maximum Admissible Transmitting Capacity
160 New Sensor Technologies in Aircraft Structural Health
Monitoring
161 Cable Load Dynamic Adjustment Based on Surface Temperature
and Thermal Circuit Model
162 Ground Fault Path Clearance system Analysis on Oil
Company's Power Distribution System
163 Available Transfer Capability Calculations Using Neural
Networks in Deregulated Power
164 Detection Algorithm of Series Arc for Electrical Fire
Prediction
165 Research for Dynamic Increasing Transmission Capacity
166 Theoretical Study on Dynamic Capacity-increase of
Transmission Lines
167 An Improved Algorithm for Fault Location in Distribution
Network
168 New Distribution Class Arrester Ground Lead Disconnector
Design
169 Investigations on the Reliability of Storage Battery
Array with High Capability
170 The Experience of Inspection of a Technical Condition
of the HV Equipment on Substation by a Method of Registration
of the Own Electromagnetic Radiations
171 Spectrum Characteristics of Piano String using Non-Harmonic
Analysis
172 Design and Construction of Grounding System in High
Voltage Laboratory at KMUTT
172 A Novel Algorithm of Dielectric Loss Measurement Based
on Orthogonal Decomposition
174 Analysis of Electric Field Distribution on the Surface
of Polymer Post Insulator Used in Electric Railway Catenary
System
175 A Survey of IGBT Fault Diagnostic Methods for Three-Phase
Power Inverters
176 New Condition Monitoring Techniques for Reliably Drive
Systems Operation
177 The measurement and simulation research of Electrified
Railway Harmonic
178 Research on Prognostic Health Management (PHM) Model
for Fighter Planes Based on Flight Data
179 Early Detecting and Protecting of Fault Arcs Based
on Chaos
180 The Research of Acoustic Emission Techniques for Non
Destructive Testing and Health Monitoring on Civil Engineering
Structures
181 A New DC power Supply Centralized Monitoring System
182 Adaptive Setting of OLTC to Improve Power Transfer
Capability of Power Systems
183 Hydromechanics Analysis for Water Cooling Stator Temperature
Field of Generator
184 Application of Independent Component Analysis on State
Inspection for Transmission Lines
185 Symptoms Detection in FMS Through Performance Indicators
Follow-Up: A Quality-Flow Approach
186 Large-scale Earthing Test Facilities at Dinorwig Power
Station
187 Design of HCI System in Monitor and Control Centre
Based on Dry-type Transformer Temperature Controller
188 The Effect of Temperature and Humidity on Corona Inception
Voltage Gradient of UHV DC Transmission Line
189 Finally Fiber Optic Sensing of Power Transformer "Hotspots"
Is Paying Off
190 Wireless Sensor for Managing Electrical Distribution
Networks
191 A Program for Design of Impulse Current Generator
Circuits
192 Implementation of Multi-function TETRA Gateway
193 Preparation of Power Transformer's CBM Implementation
In PLN P3B Jawa Bali
194 A DSP based Stator Slot Wedge Tester for Large Generators
195 Automatic Vacuum Capacitor Switch With Modified Digital
Filter
196 DSP-based high-frequency HVDC source for Verifying
Internal Pressure of Vacuum Chamber
197 Development of Coaxial-to-waveguide Antenna Attached
outer GIS for Detecting Partial Discharge
198 Development of The Portable Decomposed Gas Analyzer
for Gas Insulated Transformers
199 Development on the Zero-Flex Type Current Sensor
200 The Design of Circuit in On-line Monitoring System
for Traction Transformer Insulation
201 Preliminary Investigation for Application of MEMS
Acceleration Sensor to SF6 Gas Circuit Breaker
202 The Compact Tesla Transformer for Testing Pin Insulator
203 Energy Scavenging Technique for Powering Wireless
Sensors
204 Measurement of Arc Current Using NCIT
205 FRA Low Frequency Characteristic Study using Duality
Transformer Core Modeling
206 Condition Monitoring and Diagnosis of Power Transformers
207 Measurement Considerations using SFRA for Condition
Assessment of Power Transformers
208 Investigation of Return Voltage Measurement for the
Assessment of Power Transformers
209 Frequency Response Analysis as a technique for Moisture
Diagnostics of Power Transformers
210 Fault Gas Generation in Ester based Transformer Fluids
and Dissolved Gas Analysis (DGA)
211 Experiences of Dielectric Response Measurement in
Frequency Domain for Diagnostics of Transformer Insulation
System
212 An Algorithm for Partial Discharge Localization in
Transformers Using Winding Design Data
213 Investigating Suitable Features for Partial Discharge
Localization in Power Transformer
214 On-line Partial Discharge Detection and Location Techniques
for Condition Monitoring of Power Transformers: A Review
215 New PD Measurement Method for High Power Transformer
PDM in Service Operation
216 Pulse Interferences Elimination and Classification
of on-line UHF PD Signals for Power Transformer
217 Improvement for Diagnosing Internal Abnormalities
in Oil-Filled Transformers
218 Practical Implications of Multi-Agent Transformer
Condition Monitoring
219 On-line and Off-line Monitoring-Diagnosis System(MDS)
for Power Transformers
220 Fault Diagnosis Model of Power Transformer Based on
Combinatorial KFDA
221 Polar Mode of Frequency Response Analysis Used for
Observation of Transformer Condition
222 Detection of Deformation and Displacement of Transformer
Winding by Frequency Response Analysis
223 Influence of Measurement Parameters on FRA Characteristics
of Power Transformers
224 Diagnostic Methods for Transformers
225 Partial Discharge Pattern Analysis in Cylindrical
Insulators Model of Transformer
226 Condition Monitoring for Power Transformer
227 Design Review as a Diagnostic Tool for Power Transformers
- A Case Study
228 Transformer Condition Assessment Via Oil Quality Parameters
and DGA
229 Diagnosis of Thermal Degradation for Thermally Upgraded
Paper in Mineral Oil
230 Research on Insulation Condition Monitoring System
for Power Transformers
231 Comparison of Two Thermal Circuit Models for HST Calculation
of Oil-Immersed Transformers
232 Transformer Condition Monitoring
233 Vibration Monitoring on Power Transformer
234 Transformer Hotspot Temperature Calculation using
IEEE Loading Guide
235 Partial Discharge Monitoring in Medium Voltage Cables
236 Radiometric Partial Discharge Detection
237 Sensitivity Check for Radio Frequency Partial Discharge
Detection for Power Transformers
238 Attenuation of UHF Signals Regarding the Sensitivity
Verification for UHF PD Measurements on Power Transformers
239 Experimental Study and Feature Extraction on UHF Partial
Discharge Detection for Typical Model in Air
240 Propagation Properties of PD-induced Electromagnetic
Wave Through L-shaped Structure in model GIS measured
with UHF sensors
241 Partial Discharge Monitoring in a Noisy Environment
242 Design and Testing of UHF Sensors for Partial Discharge
Detection in Transformers
243 Wide and Narrow Band PD Detection in Plug-in Cable
Connectors in the UHF Range
244 Methods for Distinguishing Between Partial Discharges
Based on the UHF Detection Technique
245 Generation of UHF Band Aerial Noise in HV Substation
and Its Invasion Properties into GIS
246 Experimental Investigation of Positional Accuracy
for UHF Partial Discharge Location
247 Sensitivity Analysis of RF Measurements to Detect
PD in Power Cable Accessories
248 Propagation Characteristic Study of Partial Discharge
UHF Signal outside Transformer
249 UHF Characteristic of PD in Oil-Paper Insulation under
DC Voltage
250 Application of Cross-correlation Denoising Algorithm
for UHF Partial Discharge Detection
251 Study of Time Delay of UHF Signal Arrival in Location
Partial Discharge
252 On-line PD Monitoring System for Rotating Machines
Using Narrow Band Detection of EM Wave in GHz Rrange
253 Study of Anti-interference Technology for UHF PD-Detection
in Power Transformers
254 A Novel Complex Algorithm for Denoising Partial Discharge
Signals
255 A Wavelet Transform Technique for De-noising Partial
Discharge Signals
256 Experience of GIS Condition Diagnosis using Partial
Discharge Monitoring by UHF Method
257 Transfer Function as Tool for Noise Suppression and
Localization of Partial Discharges in Transformers During
On-Site Measurements
258 Enhanced Signal Processing for Conventional And Un-Conventional
PD Measuring Methods: Wavelet de-noising, Automatic Detection
Algorithms and Averaging for Arrival Time-based PD Location
in Transformers and Power Cables
259 Sensor Response Characteristics for UHF Location of
PD Sources
260 Development and On-site Application of UHF PD Detection
System to Estimate the Insulator Condition of MV Switchgear
261 Insulation Condition Assessment of HV Cables
262 Estimation of Transmission Line Parameters for Single-Core
XLPE Cables
263 On-site Application of Dielectric Response Diagnosis
on Service Aged Oil-impregnated HV Power Cables
264 High Precision Methods for Online Measurement of Capacitance
in Power Capacitors
265 Advanced Solution for On-site Diagnosis of Distribution
Power Cables
266 Dielectric Response Measurements at High Voltage Bushings
267 Diagnosis on MV XLPE Power Cable by Using Frequency
Variance Leakage Current Analysis
268 Development of External Diagnosis for Terminals in
XLPE Cables
269 Comparison of Arrival Time Estimation Methods for
Partial Discharge Pulses in Power Cables
270 A Centralized Condition Monitoring System for MV Power
Cables Based on On-line Partial Discharge Detection and
Location
271 The Application of On-Line PDM on in-service MV Cable
Terminations
272 Analysis of On-line Power Cable Signals
273 Development of Distributed On-line Monitoring System
for Dielectric Loss Tangent of High Voltage Capacitive
Apparatus
274 Experimental Study on Relationships between Partial
Discharge Signals and Apparent Discharge Magnitude in
XLPE Cable
275 Evaluation via PEA Measurements of Paper-Oil Insulation
submitted to Gamma Radiation
276 Broadband Partial Discharges Technique and Application
in the field of cable paper insulation
277 Investigation of Resistance Toward Water Tree Growth
in XLPE Insulated MV Cables Produced in the Arabian Gulf
Region
278 On-site Condition Monitoring of HV Power Cables up
to 150kV
279 Statistical Approach to Identify the Discharge Source
in MV Cables and Accessories
280 Need for Condition Monitoring and Diagnosis of Electric
Wires and Cables Used in Nuclear Power Plants
281 Partial Discharge Localization Method of Power Cable
using High-precision Synchronization by Atomic Clocks
282 A Study on the Measurement of Partial Discharges in
XLPE Power Cables using Planer Loop Sensors
283 On-line Monitoring Technology for the Insulation Condition
of Capacitive-type Substation Equipment
284 Location of Water Tree Degraded Point Along XLPE Cable
Line Using DC Voltage
285 The Transmission Characteristics of Sound Wave in
Power Cable
286 Partial Discharge Classification and Diagnosis of
Power Cable Joint by Statistical Processing
287 The Location of Partial Discharge Sources in Power
Cable: an On-line, Low-cost Solution
288 Recognition of partial discharge defects in cable
terminations
289 Study on the Frequency Spectrums of Acoustic Emission
PD Signals in XLPE Cable Accessories
290 Online Partial Discharge Detection in HV cables using
Conventional Current Transformers
291 Study on Insulation Diagnosis for XLPE Cables Using
Dumping Oscillating High Voltage
292 Simulation of Propagating Electromagnetic Wave due
to Partial Discharge in GIS using FDTD
293 Experimental Investigation of PD Diagnosis Based on
Consecutive Pulses Data
294 Influence of Inorganic Nano-filler to Partial Discharge
of Polyimide Film under High-frequency Impulses
295 Separation of Corona Noise from On-line Partial Discharge
Monitoring of Power Cables
296 Characteristics Analysis of Sensors for On-Line Partial
Discharge Measurement
297 Experiences in On-site Partial Discharge Measurements
and Prospects for PD Monitoring
298 Application of Statistical Analysis in the Asset Management
Decision Process
299 Statistical Analysis of Large Amount of Power Cables
Diagnostic Data
300 Application of Integrated Neural Network based on
Information Combination for Fault Diagnosis in Steam Turbine
Generator
301 Mechanical Equations of Material Damage and Feature
Variation for Vibration-based Monitoring and Diagnosis
302 Benefits of Comprehensive and Interactive On-Line
Monitoring and Expert Systems for Power Transformers
303 Real Time Web Based Condition Monitoring System for
Power Transformers - Case Study
304 A Web based Expert System Shell for Fault Diagnosis
and Control of Power System Equipment
305 An Enhancement of K-Nearest Neighbor Algorithm Using
Information Gain and Extension Relativity
306 Advantage of DMS Design Approach Using Knowledge Engineering
308 Characteristic Extracting for Nonlinear Diagnosis
Based on Volterra Frequency-Domain Slices
310 The Intelligent Fault diagnosis of Wind Turbine Gearbox
Based on Artificial Neural Network
311 RBFNN for Fault Diagnosis of Rotor Windings Inter-turn
Short Circuit in Turbine-Generator
312 Estimating Transformer Oil Parameters Using Polynomial
Networks
313 Studies on Layered Condition Monitoring Information
Platform Based on Multi-Agent Technology
314 Transfomer Fault Diagnosis Based on Rough Sets Theory
and Artificial Neural Networks
315 Neural Network Approach for Fault Diagnosis of Transformers
316 Development of Networks for SFRA Data Using Circuit
Synthesis
317 A Review of Intelligent Diagnostic Methods for Condition
Assessment of Insulation System in Power Transformers
318 A Data Acquisition Platform for the Development of
a Wind Turbine Condition Monitoring System
319 Application of Wavelet Package and Neural Network
in Ventilators Fault Warning
320 A Method of Data Fusion System for Fault Detection
Based on Model-based Diagnosis and Evidence Theory